The MV20-WAVE-DGGE is a complete system for DNA mutation analysis. It is fully equipped with temperature control unit, stirrer, and gradient mixer and casting accessories to perform specific mutation analysis applications. A powerful microprocessor controlled PID temperature control unit enables various mutation detection techniques to be undertaken between ambient temperature and 70°C, while the simple four screw design of the WAVE insert accelerates set up of denaturing PAGE gels. The flexibility provided by the modular design of the MV20-WAVE-DGGE and its wide range of accessories enables laboratories to switch quickly and easily between different mutation detection techniques, thereby maximizing throughput and screening efficiency. A maximum 96-sample throughput allows detection of as many mutations within a couple hours, alleviating many of the bottlenecks associated with screening for DNA mutations.
 

MS02_Electrophoresis* Marketing video

  • Maximum 96-sample throughput
  • Large format - 200x200mm glass plates
  • Use with 100ml gradient mixer to make two 1mm parallel denaturing gradient gels
  • Compatible with microplates and thermal cycler blocks
  • Ideal for detection of single base changes and polymorphisms in genomic cloned and amplified DNA fragments


* All images are for reference only, actual products might differ from the pictures above.
* Technical specifications subject to change without notice.

Cat. No. MV20-WAVE-DGGE
WAVE Electrophoresis Insert And Tank
Max. Number Of Gels 2 per run
Plate Dimension (WxH) Approx. 7.9"x7.9" (200x200mm)
Active Gel Dimension (WxH) Approx. 6.3"x6.9" (160x175mm)
Thicknesses 0.75, 1, 1.5 and 2mm
Max. Sample Capacity 96 samples; 48 per gel
Standard Combs 2x1mm 24-sample
Available Combs 1, 5, 10, 18 MC, 24, 36 MC, 48; as per MV20WAVE and Maxi units
Max. Buffer Volume 2.25gal (8.5L)
Dimension (WxLxH)  Approx. 15.9"x6.7"x1.7" (405x170x440mm)
Weight Approx. 17.6lb (8kg)
Temperature Control Unit
Temperature Control PID
Operating Temperature Range Ambient - 100ºC
Working Temperature Range (DGGE) 45-70ºC
Buffer Recirculation Mechanism Stirring
Temperature Uniformity / Stability At 37ºC ±0.05 / 0.02ºC
Setting / Display Resolution 0.1ºC
Safety Fluid-level float switch; isolated; IEC 1010/CE
Stored Temperature Values 4
Heater Power At 230V/110VAC 1.4/1.3kW
Electrical Power At 230V/100VAC 1.5/1.4kW (50-60Hz)
Recommended Power Supply MP-510
Rated Voltage 500V
Current 800mA / 500ml
Power 300W / 150W
Gradient Mixer
Total Volume 100ml
Volume Of Reservoir & Mixing Chambers 50ml
Internal Diameter Of Outlet Port 2mm
Cat. No. Product Description
MV20-WAVE-DGGE-110/220 Complete denaturing gradient gel electrophoresis system, 200x200mm; includes: temperature control unit, cam casting base, glass plates with 1mm bonded spacers, 2x24-sample combs and gradient mixer, 110V / 220V
MV20-WAVE-DGGETC-110/220 MV20-WAVE-DGGE-110 temperature control unit, 110V / 220V
MGM-100 Gradient mixer, 100ml
Cat. No Recommended Accessories Description
MU-D01 Digital Peristaltic Pump, 110 / 220V~
MU-S16 Silicon tube I.D. 0.12 inch (3.1mm), 25ft
MP-510 Lively 500V Power Supply

 

Add to inquiry

Faded Short Sleeve T-shirts

Denaturing Gradient Electrophoresis, MV20-WAVE-DGGE

MV20-WAVE-DGGE is a complete system for DNA mutation analysis

Major Science Co., Ltd (Headquarters)

No. 156, Sec. 1, Guoji Rd., Taoyuan Dist., Taoyuan City 33061, Taiwan

Phone:+886-3-3762878

Fax:+886-3-3761310

E-mail:info@majorsci.com

US Office

19959 Sea Gull Way Saratoga, CA 95070, U.S.A.

Phone: +1-408-366-9866

Fax:+1-408-446-1107

E-mail:info@majorsci.com