MS Pipeta, MSP Series
Product Description
MS pipette while providing customers with the “Best Value” combination of quality, features, service and price.
Best Accuracy & Precision
By ISO calibration and certification, MS pipette offer accurate & precise results for your research.
Applicable to universal tip
MS pipette has compatibility with a majority of brands of tips on the market.
Comfort use experisence,
Your comfort through perfect fit, lightweight & ergonomic for use MS pipette, and very easy for single-hand operation.
Product Character
Precise volume adjustment & light pipetting forces
A.Color-coded push-button Color-coded push-button
B. Operating-rod Operating-rod
C.Easy tip ejection
D. Volumeter display (Counter)
E.Connecting nut Connecting nut
F. Tip-holder Tip-holder
G. Easy tip-ejector removal Easy tip-ejector removal
Use the serial number to identify the pipette and to determine its age.
Major Science Pipette Tip Adapter
MS Pipette
• Light weight
• Soft spring system for extremely low pipetting forces
• Controlled volume setting to prevent accidental volume changes
• Large volume display
• Contoured shape: fits either small or large hands
• Large pushbutton, rounded and freely rotating
• Finger hook: takes the weight, for a more relaxed grip
• 3-position tip ejector button (left/right handed users)
• Easy on site calibration (calibration key included)
• High accuracy and precision
• A unique serial number
• UV resistance even prolonged exposure
• Fully autoclavable (121°C/0.1MPa/20 min)
Conception of new seals and lighter springs and use of high quality lubricant:
• Reduce pipetting and purge forces by 50%
• Have an easy glide of the piston
• Maintain an adequate ratio (~1/3) between pipetting forces and
purge forces to feel confident in results
• Maintain quality and robustness of our pipetting system.
Single Channel Models |
|||||||||||
Cat No. |
Volume (µL) |
SPECIFICATIONS |
ISO 8655 |
||||||||
Systematic Error |
Random Error |
Systematic Error |
Random Error |
||||||||
(µL) |
(%) |
(µL) |
(%) |
(µL) |
(%) |
(µL) |
(%) |
||||
MSP-2 |
0.2 |
±0.026 |
±13.2% |
MSP-2 |
0.2 |
±0.026 |
±13.2% |
MSP-2 |
0.2 |
||
2 |
±0.033 |
±1.7% |
2 |
±0.033 |
±1.7% |
2 |
|||||
MSP-10 |
1 |
±0.028 |
±2.8% |
MSP-10 |
1 |
±0.028 |
±2.8% |
MSP-10 |
1 |
||
10 |
±0.110 |
±1.1% |
10 |
±0.110 |
±1.1% |
10 |
|||||
MSP-20 |
2 |
±0.11 |
±5.5% |
MSP-20 |
2 |
±0.11 |
±5.5% |
MSP-20 |
2 |
||
20 |
±0.20 |
±1.0% |
20 |
±0.20 |
±1.0% |
20 |
|||||
MSP-100 |
10 |
±0.39 |
±3.9% |
MSP-100 |
10 |
±0.39 |
±3.9% |
MSP-100 |
10 |
||
100 |
±0.80 |
±0.8% |
100 |
±0.80 |
±0.8% |
100 |
|||||
MSP-200 |
20 |
±0.55 |
±2.8% |
MSP-200 |
20 |
±0.55 |
±2.8% |
MSP-200 |
20 |
||
200 |
±1.60 |
±0.8% |
200 |
±1.60 |
±0.8% |
200 |
|||||
MSP-1000 |
100 |
±3.3 |
±3.3% |
MSP-1000 |
100 |
±3.3 |
±3.3% |
MSP-1000 |
100 |
||
1000 |
±0.8 |
±8.0% |
1000 |
±0.8 |
±8.0% |
1000 |
|||||
MSP-5000 |
500 |
±13 |
±2.6% |
MSP-5000 |
500 |
±13 |
±2.6% |
MSP-5000 |
500 |
||
5000 |
±33 |
±0.7% |
5000 |
±33 |
±0.7% |
5000 |
|||||
MSP-10000 |
1000 |
±33 |
±3.3% |
MSP-10000 |
1000 |
±33 |
±3.3% |
MSP-10000 |
1000 |
||
10000 |
±60 |
±0.6% |
10000 |
±60 |
±0.6% |
10000 |
|||||
Multichannel Models |
|||||||||||
MSP-8X10 |
0.5 |
±0.09 |
±17.6% |
MSP-8X10 |
0.5 |
±0.09 |
±17.6% |
MSP-8X10 |
0.5 |
||
MSP-8X20 |
2 |
±0.11 |
±5.5% |
MSP-8X20 |
2 |
±0.11 |
±5.5% |
MSP-8X20 |
2 |
||
MSP-8X200 |
20 |
±0.6 |
±2.8% |
MSP-8X200 |
20 |
±0.6 |
±2.8% |
MSP-8X200 |
20 |
||
MSP-8X300 |
20 |
±1.1 |
±3.7% |
MSP-8X300 |
20 |
±1.1 |
±3.7% |
MSP-8X300 |
20 |
||
MSP-12X10 |
10 |
±0.22 |
±2.2% |
MSP-12X10 |
10 |
±0.22 |
±2.2% |
MSP-12X10 |
10 |
||
MSP-12X20 |
20 |
±0.40 |
±2.0% |
MSP-12X20 |
20 |
±0.40 |
±2.0% |
MSP-12X20 |
20 |
||
MSP-12X200 |
200 |
±2.2 |
±1.1% |
MSP-12X200 |
200 |
±2.2 |
±1.1% |
MSP-12X200 |
200 |
||
MSP-12X300 |
300 |
±3.3 |
±1.1% |
MSP-12X300 |
300 |
±3.3 |
±1.1% |
MSP-12X300 |
300 |
punta de pipeta Compatibilidad
Tip Compatibility |
||||||||
Major Science Single Channel Pipettes w/ Tips |
||||||||
Key: |
Ο:Not Compatible Ο:Poor FitΟ:Ok fit Ο:Good Fit -: N/A Φ: No ejection possible |
|||||||
|
Major Science Pipettes |
|||||||
Tip Brand |
Volume |
MSP-2, MSP-10 |
MSP-20 |
MSP-100 |
MSP-200 |
MSP-1000 |
MSP-5000 |
MSP-10000 |
Axygen |
10µL (short) |
Ο |
Φ |
- |
- |
- |
- |
- |
10µL (long) |
Ο |
Φ |
- |
- |
- |
- |
- |
|
20µL |
Ο |
Ο |
- |
- |
- |
- |
- |
|
100µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
200µL |
- |
Ο |
Ο |
Ο |
- |
- |
- |
|
300µL |
- |
- |
- |
Ο |
- |
- |
- |
|
1000µL |
- |
- |
- |
- |
Ο |
- |
- |
|
1100µL |
- |
- |
- |
- |
Ο |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
Ο |
- |
|
Brand |
10µl (long) |
Ο |
Φ |
- |
- |
- |
- |
- |
200µl |
- |
- |
- |
- |
||||
1000µl |
- |
- |
- |
- |
Ο |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
Ο |
- |
|
10mL |
- |
- |
- |
- |
- |
- |
Ο |
|
Greiner / Sapphire |
10µL |
Ο |
Φ |
- |
- |
- |
- |
- |
20µL |
Ο |
Φ |
- |
- |
- |
- |
- |
|
100µL |
- |
- |
Ο |
- |
- |
- |
- |
|
200µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
1000µL |
- |
- |
- |
- |
Ο |
- |
- |
|
Starlab |
10µL (long) |
Ο |
Φ |
- |
- |
- |
- |
- |
20µL |
Ο |
Ο |
Ο |
- |
- |
- |
- |
|
100µL |
- |
- |
Ο |
- |
- |
- |
- |
|
200µL |
- |
Ο |
Ο |
Ο |
- |
- |
- |
|
300µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
1000µL |
- |
- |
- |
- |
Ο |
- |
- |
|
1250µl |
- |
- |
- |
- |
- |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
Ο |
- |
|
10mL |
- |
- |
- |
- |
Ο |
- |
Ο |
|
Eppendorf |
10µL (long) |
Ο |
Φ |
- |
- |
- |
- |
- |
20µL |
Ο |
Ο |
Ο |
- |
- |
- |
- |
|
100µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
200µL |
- |
Ο |
Ο |
Ο |
- |
- |
- |
|
300µL |
- |
- |
- |
Ο |
- |
- |
- |
|
1000µL |
- |
- |
- |
- |
Ο |
- |
- |
|
1250µl |
- |
- |
- |
- |
- |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
Ο |
- |
|
10mL |
- |
- |
- |
- |
- |
- |
Ο |
|
Sartorius |
10µL |
Ο |
Φ |
- |
- |
- |
- |
- |
200µl |
- |
Ο |
Ο |
Ο |
- |
- |
- |
|
350µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
1000µl |
- |
- |
- |
- |
Ο |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
Ο |
- |
|
10mL |
- |
- |
- |
- |
- |
Ο |
||
Rainin |
10µL (short) |
Ο |
Φ |
- |
- |
- |
- |
- |
10µL (long) |
Ο |
Φ |
- |
- |
- |
- |
- |
|
20µL |
Ο |
Ο |
- |
- |
- |
- |
- |
|
100µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
200µL |
- |
Ο |
- |
Ο |
- |
- |
- |
|
350µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
1000µl |
- |
- |
- |
- |
Ο |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
Ο |
- |
|
10mL |
- |
- |
- |
- |
- |
- |
Ο |
|
Sorenson Expert |
10µL (short) |
Ο |
Φ |
- |
- |
- |
- |
- |
10µL (long) |
Ο |
Φ |
- |
- |
- |
- |
- |
|
200µL |
- |
Ο |
Ο |
Ο |
- |
- |
- |
|
300µL |
- |
- |
- |
Ο |
- |
- |
- |
|
1250µl |
- |
- |
- |
- |
Ο |
- |
- |
|
Labcon |
10µL |
Ο |
Φ |
- |
- |
- |
- |
- |
200µL |
- |
- |
Ο |
Ο |
- |
- |
- |
|
300µL |
- |
- |
- |
Ο |
- |
- |
- |
|
1000µl |
- |
- |
- |
- |
Ο |
- |
- |
|
Neptune |
10µL |
Ο |
Φ |
- |
- |
- |
- |
- |
20µl |
Ο |
Φ |
- |
- |
- |
- |
- |
|
100µl |
- |
- |
Ο |
- |
- |
- |
- |
|
200µl |
- |
- |
Ο |
Ο |
- |
- |
- |
|
300µl |
- |
- |
- |
Ο |
- |
- |
- |
|
1000µl |
- |
- |
- |
- |
Ο |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
Ο |
- |
|
Biotix |
10µl |
Ο |
Φ |
- |
- |
- |
- |
- |
20µl |
Ο |
Ο |
- |
- |
- |
- |
- |
|
100µl |
- |
- |
Ο |
- |
- |
- |
- |
|
200µl |
- |
- |
Ο |
Ο |
- |
- |
- |
|
300µl |
- |
- |
- |
Ο |
- |
- |
- |
|
1250µl |
- |
- |
- |
- |
Ο |
- |
- |
|
Thermo Art |
10µl |
Ο |
- |
- |
- |
- |
- |
- |
200µl |
- |
Ο |
Ο |
Ο |
- |
- |
- |
|
300µl |
- |
Ο |
- |
Ο |
- |
- |
- |
|
1000µl |
- |
- |
- |
- |
Ο |
- |
- |
|
1250µl |
- |
- |
- |
- |
Ο |
- |
- |
|
Thermo Finntip |
10µl (short) |
O |
- |
- |
- |
- |
- |
- |
10µl (long) |
- |
O |
- |
- |
- |
- |
- |
|
200µl |
- |
O |
O |
O |
- |
- |
- |
|
300µl |
- |
- |
- |
O |
- |
- |
- |
|
1000µl |
- |
- |
- |
- |
O |
- |
- |
|
5000µl |
- |
- |
- |
- |
- |
O |
- |
|
10mL |
- |
- |
- |
- |
- |
- |
O |
Cat. No |
Description |
MSP-2 |
MS pipette, variable volume 0.2~2μl |
MSP-10 |
MS pipette, variable volume 1~10μl |
MSP-20 |
MS pipette, variable volume 2~20μl |
MSP-100 |
MS pipette, variable volume 10~100μl |
MSP-200 |
MS pipette, variable volume 20~200μl |
MSP-1000 |
MS pipette, variable volume 100~1000μl |
MSP-5000 |
MS pipette, variable volume 500~5000μl |
MSP-10000 |
MS pipette, variable volume 1000~10000μl |
MSP-8X10 |
MS 8-ch pipette, variable volume 0.5~10μl |
MSP-8X20 |
MS 8-ch pipette, variable volume 2~20μl |
MSP-8X200 |
MS 8-ch pipette, variable volume 20~200μl |
MSP-8X300 |
MS 8-ch pipette, variable volume 20~300μl |
MSP-12X10 |
MS 12-ch pipette, variable volume 0.5~10μl |
MSP-12X20 |
MS 12-ch pipette, variable volume 2~20μl |
MSP-12X200 |
MS 12-ch pipette, variable volume 20~200μl |
MSP-ST01 |
Pipette Stand, standard version |
MSP-ST02 |
Pipette Stand, with additional alcohol sprayer |
*Technical specification and price not final and are subject to change.
MSP-ST02
Single channel / Multichannel models
Cat No. |
Volume (µL) |
SPECIFICATIONS |
ISO 8655 |
||||||
Systematic error |
Random error |
Systematic error |
Random error |
||||||
(µL) |
(%) |
(µL) |
(%) |
(µL) |
(%) |
(µL) |
(%) |
||
MSP-2 |
0.2 2 |
±0.026 ±0.033 |
±13.2% ±1.7% |
≤0.013 ≤0.015 |
≤6.6% ≤0.8% |
±0.080 ±0.080 |
±40.0% ±4.0% |
≤0.040 ≤0.040 |
≤20.0% ≤2.0% |
MSP-10 |
1 10 |
±0.028 ±0.110 |
±2.8% ±1.1% |
≤0.013 ≤0.044 |
≤1.3% ≤0.4% |
±0.120 ±0.120 |
±12.0% ±1.2% |
≤0.080 ≤0.080 |
≤8.0% ≤0.8% |
MSP-20 |
2 20 |
±0.11 ±0.20 |
±5.5% ±1.0% |
≤0.033 ≤0.066 |
≤1.7% ≤0.3% |
±0.20 ±0.20 |
±10.0% ±1.0% |
≤0.100 ≤0.100 |
≤5.0% ≤0.5% |
MSP-100 |
10 100 |
±0.39 ±0.80 |
±3.9% ±0.8% |
≤0.11 ≤0.17 |
≤1.1% ≤0.2% |
±0.80 ±0.80 |
±8.0% ±0.8% |
≤0.030 ≤0.030 |
≤3.0% ≤0.3% |
MSP-200 |
20 200 |
±0.55 ±1.60 |
±2.8% ±0.8% |
≤0.22 ≤0.33 |
≤1.1% ≤0.2% |
±1.60 ±1.60 |
±8.0% ±0.8% |
≤0.60 ≤0.60 |
≤3.0% ≤0.3% |
MSP-1000 |
100 1000 |
±3.3 ±0.8 |
±3.3% ±8.0% |
≤0.7 ≤1.7 |
≤0.7% ≤0.2% |
±8.0 ±8.0 |
±8.0% ±0.8% |
≤3.0 ≤3.0 |
≤3.0% ≤0.3% |
MSP-5000 |
500 5000 |
±13 ±33 |
±2.6% ±0.7% |
≤3.3 ≤8.8 |
≤0.7% ≤0.2% |
±40 ±40 |
±8.0% ±0.8% |
≤15 ≤15 |
≤3.0% ≤0.3% |
MSP-10000 |
1000 10000 |
±33 ±60 |
±3.3% ±0.6% |
≤6.6 ≤17.6 |
≤0.7% ≤0.2% |
±60 ±60 |
±6.0% ±0.6% |
≤30 ≤30 |
≤3.0% ≤0.3% |
MSP-8X10 |
0.5 |
±0.09 |
±17.6% |
≤0.04 |
≤8.8% |
±0.24 |
±48.0% |
≤0.16 |
≤32.0% |
MSP-8X20 |
2 |
±0.11 |
±5.5% |
≤0.09 |
≤4.4% |
±0.40 |
±20.0% |
≤0.20 |
≤10.0% |
MSP-8X200 |
20 |
±0.6 |
±2.8% |
≤0.28 |
≤1.4% |
±3.2 |
±16.0% |
≤1.20 |
≤6.0% |
MSP-8X300 |
20 |
±1.1 |
±3.7% |
≤0.39 |
≤1.3% |
±8.0 |
±26.7% |
≤3.00 |
≤10.0% |
MSP-12X10 |
10 |
±0.22 |
±2.2% |
≤0.11 |
≤1.1% |
±0.24 |
±2.4% |
≤0.16 |
≤1.6% |
MSP-12X20 |
20 |
±0.40 |
±2.0% |
≤0.17 |
≤0.8% |
±0.40 |
±2.0% |
≤0.20 |
≤1.0% |
MSP-12X200 |
200 |
±2.2 |
±1.1% |
≤0.55 |
≤0.3% |
±3.2 |
±1.6% |
≤1.20 |
≤0.6% |
MSP-12X300 |
300 |
±3.3 |
±1.1% |
≤1.10 |
≤0.4% |
±8.0 |
±2.7% |
≤3.00 |
≤1.0% |
![]() |
![]() |
![]() |
![]() |
MSP-2 |
MSP-200 |
MSP-8X10 |
MSP-12X10 |
![]() |
![]() |
![]() |
![]() |
MSP-10 |
MSP-1000 |
MSP-8X20 |
MSP-12X20 |
![]() |
![]() |
![]() |
![]() |
MSP-20 |
MSP-5000 |
MSP-8X200 |
MSP-12X200 |
![]() |
![]() |
![]() |
![]() |
MSP-100 |
MSP-10000 |
MSP-8X300 |
MSP-12X300 |